ExactBlue Quick Check — 1-Hour In-Office Dental Waterline Test

Wholesale 1-hour DUWL test kit for dental distributors and DSO purchasing programs. Standalone visual readout — no reader, no incubator, no lab work required.

How it works

The kit uses surface plasmon resonance (SPR) gold-nanoparticle chemistry tuned for a 1-hour read window. Collect the waterline sample, add to the vial, wait 60 minutes, and read the color change against the 500 CFU/mL CDC action threshold.

Detection limits

  • Action threshold: 500 CFU/mL (CDC DUWL guideline)
  • Time to result: 1 hour at room temperature

Applications

  • Dental unit waterline compliance
  • Chairside in-office monitoring
  • DSO multi-site QA programs
  • Pre/post-shock verification routines

Key features

  • Standalone visual readout — no Mobile Lab reader required
  • Meets CDC DUWL ≤500 CFU/mL guideline
  • Faster than overnight kits, no incubator
  • Manufactured in Canada under ISO 9001

Pack sizes / variants

  • EQC-015-K12 — Case of 12 kits

Sign in to view wholesale pricing and case-size availability.

View full details
Detection
Multi
Sensitivity
500.0 CFU/mL
Time to result
1 hr
Chemistry
SPR nanoparticle (gold colloid aggregation)
Equipment
Standalone (visual readout)
Made in
Canada

How it works

ExactBlue Quick Check uses the same SPR (gold nanoparticle) chemistry as AquaVial Quick Check, optimized for the 1-hour dental-waterline workflow. Standalone visual readout — no reader needed. Calibrated to the CDC 500 CFU/mL dental unit waterline action threshold.

1

Collect 20-50 ml sample in a clean cup and concentrate it using the sample concentration kit provided

2

add concentrated sample to the test vial

3

Incubate 1 hour at 35-40°C

4

Read visible color change; pass/fail at 500 CFU/mL action threshold

Sensitivity matrix

Detection limits

AStandard: 10 mL sample, 1 hr @ 35-40°C → 500 CFU/mL action threshold

Comparison

vs. traditional lab testing

Traditional method

Membrane filtration lab culture (ISO 9215 R2A media (7 day incubation))

Off-site, multi-day turnaround. Requires lab account, membrane filtration manifold, and qualified microbiology technician. Per-test cost from $40–$120 plus shipping.

With ExactBlue

On-site, same-day result

Result in 1 hr vs the 24 hr Safe Check workflow or days-long lab send-out. Standalone (no reader required).

Detection chemistry

How it detects

SPR nanoparticle (gold colloid aggregation)

Uses surface plasmon resonance nanoparticles that change color when binding to bacterial cell-wall surface markers. Direct visual readout in 15-60 minutes.

Regulatory & standards

Compliance references

  • ISO 9001:2015 QMS
  • CDC DUWL 500 CFU/mL guideline
  • ADA dental waterline guidance